Schneider RXM4AB2P7
Rated 3.5/5 based on 11 customer reviews

Schneider RXM4AB2P7

  • Category: PLC
Image
Main
range of product
Zelio Relay
series name
Miniature
product or component type
Plug-in relay
device short name
RXM
contacts type and composition
4 C/O
[Uc] control circuit voltage
230 V AC, 50/60 Hz
[Ithe] conventional enclosed thermal current
6 A at -40...55 °C
status LED
With
control type
Lockable test button
utilisation coefficient
20 %
Complementary
shape of pin
Flat
[Ui] rated insulation voltage
250 V conforming to IEC
300 V conforming to UL
300 V conforming to CSA
[Uimp] rated impulse withstand voltage
2.5 kV for 1.2/50 µs
contacts material
AgNi
[Ie] rated operational current
3 A at 28 V DC (NC) conforming to IEC
3 A at 250 V AC (NC) conforming to IEC
6 A at 28 V DC (NO) conforming to IEC
6 A at 250 V AC (NO) conforming to IEC
6 A at 277 V AC conforming to UL
8 A at 30 V DC conforming to UL
maximum switching voltage
250 V conforming to IEC
load current
6 A at 250 V AC
6 A at 28 V DC
maximum switching capacity
1500 VA/168 W
minimum switching capacity
170 mW at 10 mA, 17 V
operating rate
<= 18000 cycles/hour no-load
<= 1200 cycles/hour under load
mechanical durability
10000000 cycles
electrical durability
100000 cycles for resistive load
average coil consumption in VA
1.2 at 60 Hz
average consumption
1.2 VA 60 Hz
drop-out voltage threshold
>= 0.15 Uc
operating time
20 ms
reset time
20 ms
average resistance
15000 Ohm at 20 °C +/- 15 %
rated operational voltage limits
184...253 V AC
safety reliability data
B10d = 100000
protection category
RT I
operating position
Any position
CAD overall height
82.8 mm
CAD overall depth
80.35 mm
torque value
0.8 N.m
product weight
0.037 kg
device presentation
Complete product
Environment
dielectric strength
1300 V AC between contacts with micro disconnection insulation
2000 V AC between coil and contact with reinforced insulation
2000 V AC between poles with basic insulation
product certifications
CE
CSA
GOST
RoHS
UL
REACH
Lloyd's
standards
EN/IEC 61810-1
UL 508
CSA C22.2 No 14
ambient air temperature for storage
-40...85 °C
ambient air temperature for operation
-40...55 °C
vibration resistance
3 gn (f = 10...150 Hz), amplitude +/- 1 mm (on 5 cycles in operation)
5 gn (f = 10...150 Hz), amplitude +/- 1 mm (on 5 cycles not operating)
IP degree of protection
IP40 conforming to EN/IEC 60529
shock resistance
10 gn in operation
30 gn not operating
pollution degree
2
Main
range of product Zelio Relay
series name Miniature
product or component type Plug-in relay
device short name RXM
contacts type and composition 4 C/O
[Uc] control circuit voltage 230 V AC, 50/60 Hz
[Ithe] conventional enclosed thermal current 6 A at -40...55 °C
status LED With
control type Lockable test button
utilisation coefficient 20 %
Complementary
shape of pin Flat
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to UL
300 V conforming to CSA
[Uimp] rated impulse withstand voltage 2.5 kV for 1.2/50 µs
contacts material AgNi
[Ie] rated operational current 3 A at 28 V DC (NC) conforming to IEC
3 A at 250 V AC (NC) conforming to IEC
6 A at 28 V DC (NO) conforming to IEC
6 A at 250 V AC (NO) conforming to IEC
6 A at 277 V AC conforming to UL
8 A at 30 V DC conforming to UL
maximum switching voltage 250 V conforming to IEC
load current 6 A at 250 V AC
6 A at 28 V DC
maximum switching capacity 1500 VA/168 W
minimum switching capacity 170 mW at 10 mA, 17 V
operating rate <= 18000 cycles/hour no-load
<= 1200 cycles/hour under load
mechanical durability 10000000 cycles
electrical durability 100000 cycles for resistive load
average coil consumption in VA 1.2 at 60 Hz
average consumption 1.2 VA 60 Hz
drop-out voltage threshold >= 0.15 Uc
operating time 20 ms
reset time 20 ms
average resistance 15000 Ohm at 20 °C +/- 15 %
rated operational voltage limits 184...253 V AC
safety reliability data B10d = 100000
protection category RT I
operating position Any position
CAD overall height 82.8 mm
CAD overall depth 80.35 mm
torque value 0.8 N.m
product weight 0.037 kg
device presentation Complete product
Environment
dielectric strength 1300 V AC between contacts with micro disconnection insulation
2000 V AC between coil and contact with reinforced insulation
2000 V AC between poles with basic insulation
product certifications CE
CSA
GOST
RoHS
UL
REACH
Lloyd's
standards EN/IEC 61810-1
UL 508
CSA C22.2 No 14
ambient air temperature for storage -40...85 °C
ambient air temperature for operation -40...55 °C
vibration resistance 3 gn (f = 10...150 Hz), amplitude +/- 1 mm (on 5 cycles in operation)
5 gn (f = 10...150 Hz), amplitude +/- 1 mm (on 5 cycles not operating)
IP degree of protection IP40 conforming to EN/IEC 60529
shock resistance 10 gn in operation
30 gn not operating
pollution degree 2