Dräger Aerotest Navy (without tubes) - PN : 6525970
Rated 3.5/5 based on 11 customer reviews

Dräger Aerotest Navy (without tubes) - PN : 6525970

$3,028.00
Image

Dräger Aerotest Navy (without tubes)
PN : 6525970

Benefits
Tested breathing air
Using the Dräger Aerotest® Navy, it is possible to determine the quality of the breathing air which is supplied by a compressor or a compressed gas cylinder (up to a maximum pressure of 4500 psi). By means of the test system, the reliable testing of the breathing air is ensured according to the US Navy standard.

Pollutant detection and measurement
The Dräger Aerotest® Navy determines the quantity of various potential pollutants: It is possible to reliably determine carbon monoxide, carbon dioxide, water vapor and oil in the compressed air either individually or simultaneously. Specifically adjusted to the different fields of application of the Navy, this test system also measures the oxygen concentration of between 5% and 23% volume.

Fast and easy to use
The measuring device requires no power or tools; all connections are done by hand tightening. The device is connected via a CGA 347 connector or a 0.825 14 NGO Rh EXT connector to the high pressure compressed air system.

Always ready for use
All components of the Dräger Aerotest® Navy are arranged in a compact, convenient case and ready for use.



Technical Data
Dimensions of transport case (L x W x H) 390 x 315 x 140 mm (15.4 x 12.4 x 5.5 in)
Weight  approx. 4.2 kg (9.3 lbs)
Operating temperature  15 °C to 25 °C, 1,013 mbar
Min. operating pressure  10 bar (145 psi)
Primary pressure max.  300 bar (4500 psi)
Flow rate (l/min)  0.2 and 4.0 l/min
Supply Pressure  8.5 bar (123 psi)

Dräger Aerotest Navy (without tubes)
PN : 6525970

Benefits
Tested breathing air
Using the Dräger Aerotest® Navy, it is possible to determine the quality of the breathing air which is supplied by a compressor or a compressed gas cylinder (up to a maximum pressure of 4500 psi). By means of the test system, the reliable testing of the breathing air is ensured according to the US Navy standard.

Pollutant detection and measurement
The Dräger Aerotest® Navy determines the quantity of various potential pollutants: It is possible to reliably determine carbon monoxide, carbon dioxide, water vapor and oil in the compressed air either individually or simultaneously. Specifically adjusted to the different fields of application of the Navy, this test system also measures the oxygen concentration of between 5% and 23% volume.

Fast and easy to use
The measuring device requires no power or tools; all connections are done by hand tightening. The device is connected via a CGA 347 connector or a 0.825 14 NGO Rh EXT connector to the high pressure compressed air system.

Always ready for use
All components of the Dräger Aerotest® Navy are arranged in a compact, convenient case and ready for use.



Technical Data
Dimensions of transport case (L x W x H) 390 x 315 x 140 mm (15.4 x 12.4 x 5.5 in)
Weight  approx. 4.2 kg (9.3 lbs)
Operating temperature  15 °C to 25 °C, 1,013 mbar
Min. operating pressure  10 bar (145 psi)
Primary pressure max.  300 bar (4500 psi)
Flow rate (l/min)  0.2 and 4.0 l/min
Supply Pressure  8.5 bar (123 psi)