140ACO13000
Rated 3.5/5 based on 11 customer reviews

140ACO13000

  • Category: PLC
$2,324.84
Image

ANALOG OUT 8 CHAN CURRENT

Main
range of product
Modicon Quantum automation platform
product or component type
Analogue output module
Complementary
analogue output number
8
addressing requirement
8 output words
loop voltage
6...30 V DC
voltage drop
30 V 25 mA
analogue output range
0...20 mA 0...20000 counts
0...25 mA 0...25000 counts
4...20 mA 0...16000 counts
4...20 mA 0...4095 counts
absolute accuracy error
+/- 0.2 % of full scale at 25 °C
linearity
+/- 12 µA 4...20 mA 0...4095 counts
+/- 4 µA 0...20 mA 0...20000 counts
+/- 4 µA 0...25 mA 0...25000 counts
+/- 4 µA 4...20 mA 0...16000 counts
accuracy drift according to temperature
0.004 % of full scale/°C typical
0.007 % of full scale/°C maximum
isolation between channels and bus
1780 V for 1 minute AC
update time
5 ms
setting time
1.6 ms to 5% of the final value
3.2 ms to +/-0.1% of the final value
fault type
Open circuit 4...20 mA
bus current requirement
550 mA
power dissipation in W
5 W
external power requirement
6...30 V
marking
CE
local signalling
1 LED green bus communication is present (Active)
1 LED red external fault
8 LEDs green channel is turned on
8 LEDs red channel fault
module format
Standard
product weight
0.3 kg
Environment
product certifications
CUL
FM Class 1 Division 2
standards
CSA C22.2 No 142
UL 508
resistance to electromagnetic fields
10 V/m 80...2000 MHz conforming to IEC 801-3
ambient air temperature for operation
0...60 °C
ambient air temperature for storage
-40...85 °C
relative humidity
95 % without condensation
operating altitude
<= 5000 m

ANALOG OUT 8 CHAN CURRENT

Main
range of product Modicon Quantum automation platform
product or component type Analogue output module
Complementary
analogue output number 8
addressing requirement 8 output words
loop voltage 6...30 V DC
voltage drop 30 V 25 mA
analogue output range 0...20 mA 0...20000 counts
0...25 mA 0...25000 counts
4...20 mA 0...16000 counts
4...20 mA 0...4095 counts
absolute accuracy error +/- 0.2 % of full scale at 25 °C
linearity +/- 12 µA 4...20 mA 0...4095 counts
+/- 4 µA 0...20 mA 0...20000 counts
+/- 4 µA 0...25 mA 0...25000 counts
+/- 4 µA 4...20 mA 0...16000 counts
accuracy drift according to temperature 0.004 % of full scale/°C typical
0.007 % of full scale/°C maximum
isolation between channels and bus 1780 V for 1 minute AC
update time 5 ms
setting time 1.6 ms to 5% of the final value
3.2 ms to +/-0.1% of the final value
fault type Open circuit 4...20 mA
bus current requirement 550 mA
power dissipation in W 5 W
external power requirement 6...30 V
marking CE
local signalling 1 LED green bus communication is present (Active)
1 LED red external fault
8 LEDs green channel is turned on
8 LEDs red channel fault
module format Standard
product weight 0.3 kg
Environment
product certifications CUL
FM Class 1 Division 2
standards CSA C22.2 No 142
UL 508
resistance to electromagnetic fields 10 V/m 80...2000 MHz conforming to IEC 801-3
ambient air temperature for operation 0...60 °C
ambient air temperature for storage -40...85 °C
relative humidity 95 % without condensation
operating altitude <= 5000 m