Schneider LADN10
| range of product |
TeSys D
TeSys F |
|
|---|---|---|
| range |
TeSys
|
|
| product or component type |
Auxiliary contact block
|
|
| auxiliary contacts operation |
Instantaneous
|
|
| pole contact composition |
1 NO
|
|
| connections - terminals |
Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: flexible - with cable end
Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: flexible - without cable end Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: solid - with cable end Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: solid - without cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: flexible - with cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: flexible - without cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: solid - with cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: solid - without cable end |
| mounting location |
Front
|
|
|---|---|---|
| [Ui] rated insulation voltage |
690 V - conforming to IEC 60947-5-1
600 V - certifications CSA 600 V - certifications UL |
|
| [Ue] rated operational voltage |
690 V AC 25...400 Hz
|
|
| [Ith] conventional free air thermal current |
10 A at <= 60 °C
|
|
| Irms rated making capacity |
140 A at <= 690 V AC conforming to IEC 60947-5-1
250 A at <= 690 V DC conforming to IEC 60947-5-1 |
|
| permissible short-time rating |
100 A at 60 °C 1 s
120 A at 60 °C 500 ms 140 A at 60 °C 100 ms |
|
| protection type |
GG fuse <= 10 A rating according to operational current for Ue <= 690 V
|
|
| associated fuse rating |
10 A gG IEC 60947-5-1
|
|
| mechanical durability |
30 Mcycles
|
|
| minimum switching current |
5 mA
|
|
| minimum switching voltage |
17 V
|
|
| non-overlap time |
1.5 ms on de-energisation (no overlap between NC and NO contact)
1.5 ms on energisation (no overlap between NC and NO contact) |
|
| overlap time |
1.5 ms
|
|
| insulation resistance |
> 10 MOhm
|
|
| product weight |
0.02 kg
|
| environmental characteristic |
Normal environment
|
|
|---|---|---|
| standards |
BS 4794
EN 60947-5-1 IEC 60947-5-1 NF C 63-140 VDE 0660 |
|
| product certifications |
CSA
UL |
|
| IP degree of protection |
IP2x conforming to VDE 0106
|
|
| protective treatment |
TH conforming to IEC 60068
|
|
| ambient air temperature for operation |
-5...60 °C
|
|
| ambient air temperature for storage |
-60...80 °C
|
|
| operating altitude |
3000 m without derating in temperature
|
| range of product |
TeSys D TeSys F |
|
|---|---|---|
| range | TeSys | |
| product or component type | Auxiliary contact block | |
| auxiliary contacts operation | Instantaneous | |
| pole contact composition | 1 NO | |
| connections - terminals |
Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: flexible - with cable end Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: flexible - without cable end Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: solid - with cable end Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: solid - without cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: flexible - with cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: flexible - without cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: solid - with cable end Screw clamp terminals 2 cable 1...2.5 mm² - cable stiffness: solid - without cable end |
| mounting location | Front | |
|---|---|---|
| [Ui] rated insulation voltage |
690 V - conforming to IEC 60947-5-1 600 V - certifications CSA 600 V - certifications UL |
|
| [Ue] rated operational voltage | 690 V AC 25...400 Hz | |
| [Ith] conventional free air thermal current | 10 A at <= 60 °C | |
| Irms rated making capacity |
140 A at <= 690 V AC conforming to IEC 60947-5-1 250 A at <= 690 V DC conforming to IEC 60947-5-1 |
|
| permissible short-time rating |
100 A at 60 °C 1 s 120 A at 60 °C 500 ms 140 A at 60 °C 100 ms |
|
| protection type | GG fuse <= 10 A rating according to operational current for Ue <= 690 V | |
| associated fuse rating | 10 A gG IEC 60947-5-1 | |
| mechanical durability | 30 Mcycles | |
| minimum switching current | 5 mA | |
| minimum switching voltage | 17 V | |
| non-overlap time |
1.5 ms on de-energisation (no overlap between NC and NO contact) 1.5 ms on energisation (no overlap between NC and NO contact) |
|
| overlap time | 1.5 ms | |
| insulation resistance | > 10 MOhm | |
| product weight | 0.02 kg |
| environmental characteristic | Normal environment | |
|---|---|---|
| standards |
BS 4794 EN 60947-5-1 IEC 60947-5-1 NF C 63-140 VDE 0660 |
|
| product certifications |
CSA UL |
|
| IP degree of protection | IP2x conforming to VDE 0106 | |
| protective treatment | TH conforming to IEC 60068 | |
| ambient air temperature for operation | -5...60 °C | |
| ambient air temperature for storage | -60...80 °C | |
| operating altitude | 3000 m without derating in temperature |