Dräger-Tube Silica Gel Tube (Type G) - PN: 6728851
Dräger-Tube Silica Gel Tube (Type G)
PN: 6728851
With the Dräger silica gel tubes, the hazardous substances contained in the air are first collected by adsorption or chemisorption. The sample is then qualitatively and quantitatively tested in the laboratory using instrumental analysis such as gas chromatography (GC), high-performance liquid chromatography (HPLC), UV-VIS photometry or IR spectroscopy. Measurements: 10
· ORSA for organic compound lab analysis
| Application Range | |
| Adsorbate | organic compounds which adsorb on silical gel |
| Sorption agent | silicagel |
| Adsorption layer |
1100 mg |
| Backup layer |
450 mg |
| Tube Length |
125 mm |
| Outside diameter |
7 mm |
| Inside diameter | 5 mm |
| Advice for sample-taking |
| Because of the large quantity of silicagel in the sampling layer these silicagel tubes are specially suitable for the sampling of organic compounds which are present in high concentrations in the air sample. For example the analysis of exhaust air for the determination of the emission of a harmful substance. After sampling the tube must be sealed with the polyethylene supplied caps. |
Dräger-Tube Silica Gel Tube (Type G)
PN: 6728851
With the Dräger silica gel tubes, the hazardous substances contained in the air are first collected by adsorption or chemisorption. The sample is then qualitatively and quantitatively tested in the laboratory using instrumental analysis such as gas chromatography (GC), high-performance liquid chromatography (HPLC), UV-VIS photometry or IR spectroscopy. Measurements: 10
· ORSA for organic compound lab analysis
| Application Range | |
| Adsorbate | organic compounds which adsorb on silical gel |
| Sorption agent | silicagel |
| Adsorption layer |
1100 mg |
| Backup layer |
450 mg |
| Tube Length |
125 mm |
| Outside diameter |
7 mm |
| Inside diameter | 5 mm |
| Advice for sample-taking |
| Because of the large quantity of silicagel in the sampling layer these silicagel tubes are specially suitable for the sampling of organic compounds which are present in high concentrations in the air sample. For example the analysis of exhaust air for the determination of the emission of a harmful substance. After sampling the tube must be sealed with the polyethylene supplied caps. |