Dräger Tube Phosphine 0.1/b in Acetylene - PN: 8103341
Rated 3.5/5 based on 11 customer reviews

Dräger Tube Phosphine 0.1/b in Acetylene - PN: 8103341

$131.00
Image

Dräger Tube Phosphine 0.1/b in Acetylene (10)
PN: 8103341

Dräger-Tubes™ are used together with a Dräger tube pump for measurements of gases, vapors and aerosols, usually in air, and are one of the classic methods of gas analysis. This Dräger­Tube is used for the detection of phosphine in acetlyene and has the following standard measuring ranges: 1-15 ppm 0.1-1 ppm Measurements: 10

Application Range
Standard Measuring Range: 0.1 to 1 ppm / 1 to 15 ppm
Number of Strokes n: 10 / 1
Time for Measurement: approx. 4 min / approx. 20 s
Standard Deviation: ± 15 to 20 %
Color Change: yellow orange ä red violet

Ambient Operating Conditions
Temperature: 2 to 40 °C
Absolute Humidity: < 20 mg / L

Reaction Principle
PH3 + HgCI2 ä Hg-phosphide + HCI HCI + pH-indicator ä red violet reaction product

Cross Sensitivity
Arsin and hydrogen sulfide will be indicated with differing sensitivities.

Dräger Tube Phosphine 0.1/b in Acetylene (10)
PN: 8103341

Dräger-Tubes™ are used together with a Dräger tube pump for measurements of gases, vapors and aerosols, usually in air, and are one of the classic methods of gas analysis. This Dräger­Tube is used for the detection of phosphine in acetlyene and has the following standard measuring ranges: 1-15 ppm 0.1-1 ppm Measurements: 10

Application Range
Standard Measuring Range: 0.1 to 1 ppm / 1 to 15 ppm
Number of Strokes n: 10 / 1
Time for Measurement: approx. 4 min / approx. 20 s
Standard Deviation: ± 15 to 20 %
Color Change: yellow orange ä red violet

Ambient Operating Conditions
Temperature: 2 to 40 °C
Absolute Humidity: < 20 mg / L

Reaction Principle
PH3 + HgCI2 ä Hg-phosphide + HCI HCI + pH-indicator ä red violet reaction product

Cross Sensitivity
Arsin and hydrogen sulfide will be indicated with differing sensitivities.