Specifications
Rated Voltage: 12/24 volts DC, nominal
Output Voltage Range: 10.2 to 30 volts DC
Outputs per Module: 32 (two isolated groups of 16 outputs each)
 
Isolation:
 Field to Backplane (optical) and to Frame Ground: 250 VAC continuous; 1500 VAC for 1 minute
 Group to Group: 250 VAC continuous; 1500 VAC for 1 minute
 
Module ID: 0x059h
Output Current: 0.75 Amps per point
Power Consumption: 300 mA (maximum) from 5 volt bus on backplane;
Thermal Derating: No derating at 24VDC. At 30VDC, outputs are derated above 42 degrees C as shown below.
External Power Supply: +12 VDC to +30 VDC, 12/24 VDC nominal
 
External Power Supply Current Required (not including load current):
 Module version CC and later: 72 mA/group with all outputs commanded Off, 132 mA/group with all outputs commanded ON
 Module version BC and earlier: 72 mA/group with all outputs commanded OFF, 100 mA/group with all outputs commanded ON
 
Output Characteristics
 Inrush Current: 3 Amps supplied for 10ms without ESCP trip
 Output Voltage Drop: 0.3 volt DC maximum
 Steady-state overcurrent trip: 5 Amps typical per point
 Output Leakage Current: 0.1mA maximum
 On Response Time: 0.5ms maximum
 Off Response Time: 0.5ms maximum
 Protection: Short-circuit protection, overcurrent protection, overtemperature protection, all with auto recovery.
Product Number: IC694MDL754   Specifications Rated Voltage: 12/24 volts DC, nominal Output Voltage Range: 10.2 to 30 volts DC Outputs per Module: 32 (two isolated groups of 16 outputs each)   Isolation:  Field to Backplane (optical) and to Frame Ground: 250 VAC continuous; 1500 VAC for 1 minute  Group to Group: 250 VAC continuous; 1500 VAC for 1 minute   Module ID: 0x059h Output Current: 0.75 Amps per point Power Consumption: 300 mA (maximum) from 5 volt bus on backplane; Thermal Derating: No derating at 24VDC. At 30VDC, outputs are derated above 42 degrees C as shown below. External Power Supply: +12 VDC to +30 VDC, 12/24 VDC nominal   External Power Supply Current Required (not including load current):  Module version CC and later: 72 mA/group with all outputs commanded Off, 132 mA/group with all outputs commanded ON  Module version BC and earlier: 72 mA/group with all outputs commanded OFF, 100 mA/group with all outputs commanded ON   Output Characteristics  Inrush Current: 3 Amps supplied for 10ms without ESCP trip  Output Voltage Drop: 0.3 volt DC maximum  Steady-state overcurrent trip: 5 Amps typical per point  Output Leakage Current: 0.1mA maximum  On Response Time: 0.5ms maximum  Off Response Time: 0.5ms maximum  Protection: Short-circuit protection, overcurrent protection, overtemperature protection, all with auto recovery.